Jump to content

Search the Community

Showing results for tags 'Calculations'.



More search options

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • Mod Section
  • The Basics
    • Introduce Yourself
    • Know how for starters
    • This Website
    • Test
  • Green Stuff
    • General Talk
    • Bugs, Pests & Diseases
    • Budshots
    • Growguide Talk
    • Growguide
    • Organic growing
  • Genetics
    • Genetics
  • Tests, Experiments and Science
    • OpenGrow tests, reviews and interviews
    • OpenGrow Test Lab
  • Indoor Growing
    • Indoor Talk
    • Grow Reports
    • Micro-Fluo
    • Grow room design
    • Hydro
  • Outdoor Growing
    • Outdoor Talk
    • Grow reports
    • Guerrilla
  • Breeders Forums
    • Sannie's Corner
    • Dynasty Seeds
    • Eskobar Seeds
    • Underground Seed Collective
    • NAW seeds
    • Upcoming breeders
  • The use
    • The Kitchen
    • Medicinal Cannabis
    • Smoke reports
    • The Hash maker
  • The Lounge
    • Current affairs
    • The Grapevine

Categories

  • Articles
    • Forum Integration
    • Frontpage
  • Pages
  • Miscellaneous
    • Databases
    • Templates
    • Media

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


AIM


MSN


Website URL


ICQ


Yahoo


Jabber


Skype


Location


Interests

Found 1 result

  1. Hello everyone. I am currently designing a small cabinet to grow in. I am asking a few obvious questions but I dont want to waste money and materials due to incorrect calculations. On the intake I am planning to fit a HEPA filter but no intake fan and I am wondering how much this will affect my grow? Want to use a exhaust fan large enough to compensate for no intake fan. I have calculated the airflow requirements as below and just need to know whether it is accurate and sufficient. Interior dimensions as follows: L: 650 mm (25 1/2") W: 450 mm ( 17 2/3") H: 1060mm ( 41 2/3") Total volume = 0.31 m3 (10.95 ft3) At one airchange a minute that gives me a minimum Fan requirement of 0.31 m3 X 60 = 18.6m3 per hr lets round it off to 19 m3 (671cft) Then I add 35% (6.65m3)[235cft] to allow for the use of a carbon filter Also adding 20% (3.8m3)[ 134cft] to compensate for not having an intake fan And lastly adding another 35% (6.65m3) [235cf] to compensate for the HEPA filter on the intake... This gives me a total of 36.1m3 (1274cft) for the fan to move in an hour in order to change out the air once every minute. Am I then correct in assuming that thusly I would need a fan with a rating of at least 36.1m3/hr OR 1274cft per hour /60 minutes = 21.3cfm ?? I will be using one 150W CFL growlight and will not grow more than two plants in a DWC-LP -aeroponic hybrid system.I may possibly upgrade to another 150W CFL in future. I have grown outdoors but am new to indoor growing and want to have a small cabinet to sustain me during winter. I have the following questions: > Will I have sufficient airflow with the fan calculations as above to skip a circulation fan as my space is limited? >How do I calculate the size of the intake? > Can I adjust the intake/ extraction hole size ratio in order to compensate for the lack of a circulating fan? Any help or advice is appreciated.
×
×
  • Create New...